{"id":57748,"date":"2020-03-08T16:45:07","date_gmt":"2020-03-08T15:45:07","guid":{"rendered":"https:\/\/acustica-aia.it\/?p=57748"},"modified":"2020-03-08T16:48:50","modified_gmt":"2020-03-08T15:48:50","slug":"amended-the-annex-iii-to-directive-2002-49-ec-on-assessment-methods-for-harmful-effects-of-environmental-noise","status":"publish","type":"post","link":"https:\/\/acustica-aia.it\/en\/amended-the-annex-iii-to-directive-2002-49-ec-on-assessment-methods-for-harmful-effects-of-environmental-noise\/","title":{"rendered":"Amended the Annex III to Directive 2002\/49\/EC on assessment methods for harmful effects of environmental noise"},"content":{"rendered":"<section class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text]<\/p>\n<p id=\"d1e40-132-1\" class=\"doc-ti\">With the approval of the <span style=\"color: #339832;\"><a style=\"color: #339832;\" href=\"https:\/\/eur-lex.europa.eu\/legal-content\/EN\/TXT\/?uri=uriserv:OJ.L_.2020.067.01.0132.01.ENG&amp;toc=OJ:L:2020:067:TOC\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>Directive n. 2020\/367 of 4 March 2020<\/strong><\/a><\/span> the European Commission has amended the Annex III to Directive 2002\/49\/EC as regards the establishment of assessment methods for harmful effects of environmental noise.<\/p>\n<p>Here following the text just approved that Member States shall have to bring into force in their laws, regulations and administrative provisions by 31 December 2021 at the latest.<\/p>\n<p>&nbsp;<\/p>\n<p id=\"d1e43-134-1\" class=\"doc-ti quotation-ti\" style=\"text-align: center;\"><strong>ANNEX III<\/strong><\/p>\n<p class=\"doc-ti quotation-ti\" style=\"text-align: center;\"><strong>ASSESSMENT METHODS FOR HARMFUL EFFECTS<\/strong><\/p>\n<p id=\"d1e54-134-1\" class=\"ti-grseq-1\"><strong>1.\u00a0\u00a0\u00a0<span class=\"bold\">Set of harmful effects<\/span><\/strong><\/p>\n<p class=\"normal\">For the purposes of the assessment of harmful effects the following shall be considered:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">ischaemic heart disease (IHD) corresponding to codes BA40 to BA6Z of the international classification ICD-11 established by the World Health Organisation;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">high annoyance (HA);<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">high sleep disturbance (HSD).<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p id=\"d1e75-134-1\" class=\"ti-grseq-1\"><strong>2.\u00a0\u00a0\u00a0<span class=\"bold\">Calculation of harmful effects<\/span><\/strong><\/p>\n<p class=\"normal\">The harmful effects shall be calculated by either of the following:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">the relative risk (RR) of a harmful effect defined as<\/p>\n<p class=\"separator\"><img decoding=\"async\" src=\"https:\/\/eur-lex.europa.eu\/resource.html?uri=uriserv:OJ.L_.2020.067.01.0132.01.ENG.xhtml.L_2020067EN.01013402.tif.jpg\" alt=\"Image 1\" width=\"437\" height=\"90.5\" \/><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">the absolute risk (AR) of a harmful effect defined as<\/p>\n<p class=\"separator\"><img decoding=\"async\" src=\"https:\/\/eur-lex.europa.eu\/resource.html?uri=uriserv:OJ.L_.2020.067.01.0132.01.ENG.xhtml.L_2020067EN.01013403.tif.jpg\" alt=\"Image 2\" width=\"352.5\" height=\"55\" \/><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p id=\"d1e97-134-1\" class=\"ti-grseq-1\"><strong>2.1.\u00a0\u00a0\u00a0<span class=\"bold\">IHD<\/span><\/strong><\/p>\n<p class=\"normal\">For the calculation of the RR, with respect to the harmful effect of IHD and concerning the incidence rate (<span class=\"italic\">i),<\/span> the following dose-effect relations shall be used:<\/p>\n<p class=\"separator\"><img decoding=\"async\" src=\"https:\/\/eur-lex.europa.eu\/resource.html?uri=uriserv:OJ.L_.2020.067.01.0132.01.ENG.xhtml.L_2020067EN.01013404.tif.jpg\" alt=\"Image 3\" width=\"598\" height=\"71.5\" \/><\/p>\n<p class=\"normal\">for road noise.<\/p>\n<p id=\"d1e115-134-1\" class=\"ti-grseq-1\"><strong>2.2.\u00a0\u00a0\u00a0<span class=\"bold\">HA<\/span><\/strong><\/p>\n<p class=\"normal\">For the calculation of the AR, with respect to the harmful effect of HA the following dose-effect relations shall be used:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"100%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"separator\"><img decoding=\"async\" src=\"https:\/\/eur-lex.europa.eu\/resource.html?uri=uriserv:OJ.L_.2020.067.01.0132.01.ENG.xhtml.L_2020067EN.01013501.tif.jpg\" alt=\"Image 4\" width=\"460\" height=\"28\" \/><\/p>\n<p class=\"normal\">for road noise;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"100%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"separator\"><img decoding=\"async\" src=\"https:\/\/eur-lex.europa.eu\/resource.html?uri=uriserv:OJ.L_.2020.067.01.0132.01.ENG.xhtml.L_2020067EN.01013502.tif.jpg\" alt=\"Image 5\" width=\"460\" height=\"28\" \/><\/p>\n<p class=\"normal\">for railway noise;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"100%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"separator\"><img decoding=\"async\" src=\"https:\/\/eur-lex.europa.eu\/resource.html?uri=uriserv:OJ.L_.2020.067.01.0132.01.ENG.xhtml.L_2020067EN.01013503.tif.jpg\" alt=\"Image 6\" width=\"460\" height=\"28\" \/><\/p>\n<p class=\"normal\">for aircraft noise.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p id=\"d1e142-134-1\" class=\"ti-grseq-1\"><strong>2.3.\u00a0\u00a0\u00a0<span class=\"bold\">HSD<\/span><\/strong><\/p>\n<p class=\"normal\">For the calculation of the AR, with respect to the harmful effect of HSD the following dose-effect relations shall be used:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"100%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"separator\"><img decoding=\"async\" src=\"https:\/\/eur-lex.europa.eu\/resource.html?uri=uriserv:OJ.L_.2020.067.01.0132.01.ENG.xhtml.L_2020067EN.01013504.tif.jpg\" alt=\"Image 7\" width=\"458.5\" height=\"28.5\" \/><\/p>\n<p class=\"normal\">for road noise;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"100%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"separator\"><img decoding=\"async\" src=\"https:\/\/eur-lex.europa.eu\/resource.html?uri=uriserv:OJ.L_.2020.067.01.0132.01.ENG.xhtml.L_2020067EN.01013505.tif.jpg\" alt=\"Image 8\" width=\"453.5\" height=\"28.5\" \/><\/p>\n<p class=\"normal\">for railway noise;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"100%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"separator\"><img decoding=\"async\" src=\"https:\/\/eur-lex.europa.eu\/resource.html?uri=uriserv:OJ.L_.2020.067.01.0132.01.ENG.xhtml.L_2020067EN.01013506.tif.jpg\" alt=\"Image 9\" width=\"450.5\" height=\"28.5\" \/><\/p>\n<p class=\"normal\">for aircraft noise.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p id=\"d1e169-134-1\" class=\"ti-grseq-1\"><strong>3.\u00a0\u00a0\u00a0<span class=\"bold\">Assessment of harmful effects<\/span><\/strong><\/p>\n<p class=\"normal\">3.1.\u00a0\u00a0\u00a0The exposure of the population shall be assessed independently for each noise source and harmful effect. Where the same people are simultaneously exposed to different noise sources, the harmful effects may -in general- not be cumulated. However, those effects may be compared to assess the relative importance of each noise.<\/p>\n<p id=\"d1e183-134-1\" class=\"ti-grseq-1\"><strong>3.2.\u00a0\u00a0\u00a0<span class=\"bold\">Assessment for IHD<\/span><\/strong><\/p>\n<p class=\"normal\">3.2.1.\u00a0\u00a0\u00a0<span class=\"bold\">For IHD in the case of railway and aircraft noise<\/span>, the population exposed above adequate L<span class=\"sub\">den<\/span> levels is estimated as subject to an increased risk of IHD, while the exact number <span class=\"italic\">N<\/span> of cases of IHD cannot be calculated.<\/p>\n<p class=\"normal\">3.2.2.\u00a0\u00a0\u00a0<span class=\"bold\">For<\/span> <span class=\"bold\">IHD in the case of road noise,<\/span> the proportion of cases of the specific harmful effect in the population exposed to a RR that is calculated to be caused by environmental noise is derived, for the noise source <span class=\"italic\">x<\/span> (road), harmful effect <span class=\"italic\">y<\/span> (IHD) and for the incidence <span class=\"italic\">i<\/span> by:<\/p>\n<p class=\"separator\"><img decoding=\"async\" src=\"https:\/\/eur-lex.europa.eu\/resource.html?uri=uriserv:OJ.L_.2020.067.01.0132.01.ENG.xhtml.L_2020067EN.01013507.tif.jpg\" alt=\"Image 10\" width=\"243.5\" height=\"29.5\" \/><\/p>\n<p class=\"normal\">Where:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\"><span class=\"italic\">PAF<span class=\"sub\">x,y<\/span> <\/span> is the population attributable fraction,<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">the set of <span class=\"italic\">j<\/span> noise bands is made up of single bands spanning over a maximum of 5 dB (e.g.: 50-51 dB, 51-52 dB, 52-53 dB, etc. or 50-54 dB, 55-59 dB, 60-64 dB, etc.),<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\"><span class=\"italic\">p<span class=\"sub\">j<\/span> <\/span> is the proportion of the overall population <span class=\"italic\">P<\/span> in the area assessed that is exposed to the <span class=\"italic\">j<\/span>-th exposure band, which is associated with a given RR of a specific harmful effect <span class=\"italic\">RR<span class=\"sub\">j,x,y<\/span> <\/span>. The <span class=\"italic\">RR<span class=\"sub\">j,x,y<\/span> <\/span> is calculated using the formulas described in point 2 of this Annex, calculated at the central value of each noise band (e.g.: depending on availability of data, at 50,5 dB for the noise band defined between 50-51 dB, or 52 dB for the noise band 50-54 dB).<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">3.2.3.\u00a0\u00a0\u00a0<span class=\"bold\">For IHD in the case of road noise, the total number <span class=\"italic\">N<\/span> of cases of IHD<\/span> (people affected by the harmful effect <span class=\"italic\">y<\/span>; number of attributable cases) due to the source <span class=\"italic\">x<\/span> is then:<\/p>\n<p class=\"normal\"><span class=\"italic\">N<span class=\"sub\">x,y<\/span> <\/span> = <span class=\"italic\">PAF<span class=\"sub\">x,y,i<\/span> <\/span> * <span class=\"italic\">I<span class=\"sub\">y<\/span> <\/span> * <span class=\"italic\">P<\/span> (Formula 11)<\/p>\n<p class=\"normal\">for road.<\/p>\n<p class=\"normal\">Where:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\"><span class=\"italic\">PAF<span class=\"sub\">x,y,i<\/span> <\/span> is calculated for the incidence <span class=\"italic\">i,<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\"><span class=\"italic\">Iy<\/span> is the incidence rate of IHD in the area under assessment, that can be obtained from statistics on health for the region or country where the area is,<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\"><span class=\"italic\">P<\/span> is the total population of the area under assessment (the sum of the population in the different noise bands).<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">3.3.\u00a0\u00a0\u00a0<span class=\"bold\">For<\/span> <span class=\"bold\">HA and HSD in the case of road, railway and aircraft noise, the total number <span class=\"italic\">N<\/span> of people affected by the harmful effect <span class=\"italic\">y<\/span> <\/span> (number of attributable cases) due to the source <span class=\"italic\">x<\/span>, for each combination of noise source <span class=\"italic\">x<\/span> (road, railway or aircraft source) and harmful effect <span class=\"italic\">y<\/span> (HA, HSD), is then:<\/p>\n<p class=\"separator\"><img decoding=\"async\" src=\"https:\/\/eur-lex.europa.eu\/resource.html?uri=uriserv:OJ.L_.2020.067.01.0132.01.ENG.xhtml.L_2020067EN.01013601.tif.jpg\" alt=\"Image 11\" width=\"206\" height=\"17.5\" \/><\/p>\n<p class=\"normal\">Where:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\"><span class=\"italic\">AR<span class=\"sub\">x,y<\/span> <\/span> is the AR of the relevant harmful effect (HA, HSD), and is calculated using the formulas set out in point 2 of this Annex, calculated at the central value of each noise band (e.g.: depending on availability of data, at 50,5 dB for the noise band defined between 50-51 dB, or 52 dB for the noise band 50-54 dB),<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\"><span class=\"italic\">n<span class=\"sub\">j<\/span> <\/span> is the number of people that is exposed to the <span class=\"italic\">j<\/span>-th exposure band.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p id=\"d1e368-134-1\" class=\"ti-grseq-1\"><strong>4.\u00a0\u00a0\u00a0<span class=\"bold\">Future revisions<\/span><\/strong><\/p>\n<p class=\"normal\">The dose-effect relations introduced by future revisions of this Annex will concern in particular:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">the relation between annoyance and L<span class=\"sub\">den<\/span> for industrial noise,<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">the relation between sleep disturbance and L<span class=\"sub\">night<\/span> for industrial noise.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">If necessary, specific dose-effect relations could be presented for:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">dwellings with special insulation against noise as defined in Annex VI,<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">dwellings with a quiet fa\u00e7ade as defined in Annex VI,<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">different climates\/different cultures,<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">vulnerable groups of the population,<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">tonal industrial noise,<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">impulsive industrial noise and other special cases.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text] With the approval of the Directive n. 2020\/367 of  [&#8230;]<\/p>\n","protected":false},"author":6415,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[299],"tags":[],"class_list":["post-57748","post","type-post","status-publish","format-standard","hentry","category-notizie-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/acustica-aia.it\/en\/wp-json\/wp\/v2\/posts\/57748","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acustica-aia.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/acustica-aia.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/acustica-aia.it\/en\/wp-json\/wp\/v2\/users\/6415"}],"replies":[{"embeddable":true,"href":"https:\/\/acustica-aia.it\/en\/wp-json\/wp\/v2\/comments?post=57748"}],"version-history":[{"count":3,"href":"https:\/\/acustica-aia.it\/en\/wp-json\/wp\/v2\/posts\/57748\/revisions"}],"predecessor-version":[{"id":57751,"href":"https:\/\/acustica-aia.it\/en\/wp-json\/wp\/v2\/posts\/57748\/revisions\/57751"}],"wp:attachment":[{"href":"https:\/\/acustica-aia.it\/en\/wp-json\/wp\/v2\/media?parent=57748"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/acustica-aia.it\/en\/wp-json\/wp\/v2\/categories?post=57748"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/acustica-aia.it\/en\/wp-json\/wp\/v2\/tags?post=57748"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}